Wyłączniki główne Eaton | Raptor Supplies Polska

Wyłączniki główne firmy EATON


Eaton main circuit breakers are used to protect the electrical system from overloads and short circuits, automatically interrupting the flow of electricity, preventing damage to equipment and minimising the risk of electrical hazards.

FILTRY
StylModelCena
A
1MCB600R
29157,12zł
Zapytanie ofertowe
B
3MHCB800R
50175,81zł
Zapytanie ofertowe
B
3MHCB600R
39882,87zł
Zapytanie ofertowe
B
3MHCB250R
22608,72zł
Zapytanie ofertowe
C
1MCB500R
28366,83zł
Zapytanie ofertowe
C
1MCB250R
22477,05zł
Zapytanie ofertowe
C
1MCB1200R
58286,07zł
Zapytanie ofertowe
C
1MCB900R
157909,23zł
Zapytanie ofertowe
C
1MCB300R
23606,01zł
Zapytanie ofertowe
B
3MHCB300R
23973,03zł
Zapytanie ofertowe
B
3MHCB1000R
71919,09zł
Zapytanie ofertowe
D
1MCB400R
25929,99zł
Zapytanie ofertowe
E
1MCB1000R
48501,18zł
Zapytanie ofertowe
B
3MHCB700R
46111,41zł
Zapytanie ofertowe
C
1MCB700R
112489,65zł
Zapytanie ofertowe
B
3MHCB900R
54221,49zł
Zapytanie ofertowe
B
3MHCB1200R
82861,20zł
Zapytanie ofertowe
F
1MHCBE1200RC
236646,18zł
Zapytanie ofertowe
E
1MHCB1000R
53478,27zł
Zapytanie ofertowe
C
1MCB350R
24753,96zł
Zapytanie ofertowe
B
3MHCB350R
26014,77zł
Zapytanie ofertowe
D
1MHCB400R
27124,83zł
Zapytanie ofertowe
A
1MHCB600R
31669,20zł
Zapytanie ofertowe
B
3MHCB400R
28009,26zł
Zapytanie ofertowe
G
1MHCB800R
38687,94zł
Zapytanie ofertowe
C
1MHCB1200R
63865,35zł
Zapytanie ofertowe
G
1MCB800R
32685,39zł
Zapytanie ofertowe
B
3MHCB500R
34265,88zł
Zapytanie ofertowe

Korzyści

  • These MCBs can accommodate wire sizes ranging from 1 AWG to 750 kcmil, offering versatility in wiring configurations.
  • They have a high interrupt rating of up to 1000 kAIC, ensuring effective protection by swiftly interrupting the circuit in the event of overloads or short circuits.
  • These MCBs are equipped with advanced NEMA 3R enclosures, enhancing their resistance to weather and environmental factors for outdoor installations.

Często Zadawane Pytania

What factors should be considered when selecting an Eaton main circuit breaker for a specific application?

Consider factors such as the electrical load, interrupting capacity, and environmental conditions. Ensure compliance with local electrical codes and consult with a professional for guidance on the most suitable breaker for your application.

How often should Eaton main circuit breakers be inspected for wear and tear?

Regular inspections are recommended, especially after prolonged use or exposure to harsh conditions. Check for signs of wear, corrosion, or loose components and address any issues promptly.

How should I clean an Eaton main circuit breaker to maintain its performance?

Cleaning involves using a dry cloth to remove dust and debris. Ensure the breaker is de-energised before cleaning and follow manufacturer guidelines for specific cleaning procedures.

Jakie punkty należy sprawdzić przed uruchomieniem wyłącznika MCB?

  • Conduct a thorough inspection of the unit for cracks, chipping, discolouration, or any signs of overheating. Ensure the terminals and connectors are securely tightened and inspect the mounting hardware.
  • Maintain cleanliness around the breaker by using an enclosure. Eliminate dust, dirt, grease, moisture, foreign contaminants or any safety hazards in the vicinity of the circuit breaker area.
  • Utilise the optional push-to-trip button on the bottom side of the unit to perform a mechanical test of the circuit breaker.
  • Verify that the unit's mechanical linkages, such as the toggle actuator, move freely by toggling the unit ON and OFF multiple times.

Jesteśmy tutaj aby pomóc!

Szukasz części nie wymienionej tutaj?